Live SCADA Monitoring Room
Real-time telemetry, inverter string telemetry, and environmental sensors.
Simulation:
BESS System Report
Active Power Output
114.2 MW
76.1% of Rated Capacity
Daily Accumulation
785.4 MWh
₹25.5 Lakhs revenue
Plane of Array (POA)
895 W/m²
Pyranometer S-01
PV Module Temp
47.8 °C
Ambient: 32.4 °C
Inverter Online Ratio
48 / 48
0 Tripped • 100% Online
Live Performance Ratio
82.6%
Nominal Standard
Grid Frequency
50.02 Hz
Bus Voltage: 33.2 kV
Grid Power Factor
0.99
Lagging • Active Sync
Hourly Telemetry Curve
Real-time diurnal generation (MWh) & solar irradiance correlation
Utility BESS Container Array • SCADA Dispatch Control
4-Hour LFP Storage • Frequency Balancing • TOD Tariff Arbitrage
State of Charge (SoC)
78.4%
188.2 MWh available of 240 MWh
Active Dispatch Power
+42.5 MW
Peak Discharging (Exporting to Grid)
Rated Inverter: 60 MW (0.25C LFP)
Round-Trip Efficiency (RTE)
89.2%
State of Health (SoH): 98.6%
642 Cumulative Cycles
Today Arbitrage Revenue
₹4.25 Lakhs
Peak Tariff: ₹8.45 / Solar Soak: ₹2.40
Net Margin Spread: +₹6.05 / kWh
24-Hour BESS Dispatch & State of Charge Schedule
SLDC Synchronized
Blue = Mid-Day Solar Charge | Green = Evening Peak Discharge
Container Rack Telemetry & Thermal BMS
Liquid chilling loop • Novec 1230 fire safety
Active Rack Containers:
32 / 32 Online (100%)
Mean Cell Temp:
28.4 °C (Liquid Cooled R134a)
HVAC Aux Consumption:
145 kW (0.24% of Gross)
DC Bus Operating Voltage:
1,250 V DC • 33 kV Substation
Fire Suppression System:
Aerosol Novec 1230 Normal
Dispatch Algorithm:
Abhivanta AI™ Arbitrage v2.6
BESS Cell-Tier Telemetry • 32-Rack Delta-V ($\Delta V$) Heatmap
Cell voltage variance ($\Delta V < 18\text{ mV}$), thermal gradient, and active balancing status
All 32 Racks Balanced
Mean Cell: 3.284 V • $\Delta V$: 12 mV
Real-time battery pack container banks: click any rack block to inspect individual thermal probe and BMS node.
Nominal (<3.32V)
Balancing Active
Float Standby
SLDC Grid Dispatch • Substation Single-Line Diagram (SLD)
Real-time Deviation Settlement Mechanism (DSM), breaker control, and 33kV/220kV busbar telemetry
DSM Compliant (±1.4%)
CEA Grid Code 50.02 Hz
SLDC Schedule MW
112.5 MW
Declared Day-Ahead Schedule
Actual Grid Injection
114.2 MW
Deviation: +1.7 MW (+1.51%)
DSM Tolerance Band
±10.0%
CERC Band Compliant (Zero Penalty)
DSM Penalty Risk
₹0.00 / Block
96 Time-Blocks Cleared Nominal
Remote Plant Control Console
Command Interlock: Armed
Feeder CB-01 • Solar PV
Status: Closed (33 kV Connected)
Feeder CB-02 • BESS Container Bay
Status: Closed (Grid Injected)
SLDC Active Curtailment Setpoint:
100% (No Curtailment)
50% (Grid Congestion)
100% (Full Dispatch)
High Wind • Emergency Stow Mode
Drive single-axis trackers to 0° horizontal safety flat
All control commands cryptographically logged to Abhivanta SCADA Audit Trail with operator verification.
Inverter Block Operational Matrix
Detailed health status of decentralized central inverter blocks
Abhivanta AI™ Inverter Health & Dispatch Analytics Engine
AI Model: LSTM-Neural-v2.6
Soiling Vision ML
Optimal
1.12% Loss
Autonomous waterless robotic cleaning scheduled for Block B-08 at 22:00 IST to prevent clipping.
Trigger threshold: 1.80%
Day-Ahead Forecast
98.4% Conf
3,480.5 MWh
Predicted peak irradiance of 960 W/m² at 12:45 IST. SLDC schedule submitted automatically with zero DSM error.
DSM Deviation Risk: 0.00%
BESS Arbitrage Optimization
Dispatched
₹8.45 / kWh Peak
Storing 120 MWh mid-day surplus; discharging during 18:30-22:30 IST evening grid peak for maximum merchant revenue.
Net Value Add: +₹4.2 Lakhs/Day